![]() |
![]() |
Characteriscics
| Stable and adjustable output power | |
| Over-temperature and over-current protection | |
| External modulation available | |
| Suitable for scientific research, medical therapeutics, biotechnology, laser show, etc |
Specification
Model
|
LA series
|
Wavelength
|
532nm
|
Output
power
|
1-300mW
|
Beam Mode
|
TEM00, Multi-longitude
|
Power stability(RMS)
|
<5% @8hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling System
|
TEC
|
Model
|
LB series
|
Wavelength
|
532nm
|
Output
power
|
300-800mW
|
Beam Mode
|
TEM00, Multi-longitude
|
Power stability(RMS)
|
<5% @8hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling system
|
TEC
|
Characteriscics
| Stable and adjustable output power | |
| Over-temperature and over-current protection | |
| Single Longitude mode, leading to narrow linewidth and wide coherent length | |
| Highly stable output beam, with low amplitude noise | |
| Suitable for raman spetroscopy, fluorescence excit-ation, holograph, medical therapeutics, | |
| biotechnology, etc. |
Specification
Wavelength
|
532nm
|
Output
power
|
1-200mW
|
Beam Mode
|
TEM00, Single-longitude
|
Power stability(RMS)
|
<5% @8hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling system
|
TEC
|
Characteriscics
| Stable and adjustable output power | |
| Over-temperature and over-current protection | |
| External modulation available | |
| Highly stable output beam, with low amplitude noise | |
| Suitable for raman spetroscopy, fluorescence excit-ation, medical therapeutics, | |
| biotechnology, etc. |
Specification
Wavelength
|
532nm
|
Output
power
|
1-300mW
|
Beam Mode
|
TEM00, Multi-longitude
|
Power stability(RMS)
|
<5% @8hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling system
|
TEC
|
Characteriscics
| integrated structure, small size, plug and play | |
| Over-temperature and over-current protection | |
| External modulation available | |
| Suitable for laser precision measuring, laser show applications, etc |
Specification
Wavelength
|
532nm
|
Output
power
|
1-180mW
|
Beam Mode
|
TEM00, Multi-longitude
|
Power stability(RMS)
|
<5% @8hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling system
|
TEC
|
Characteriscics
| Stable and adjustable output power | |
| Over-temperature and over-current protection | |
| External modulation available (<5KHz 5V TTL) | |
| Highly stable output beam, with low amplitude noise | |
| Suitable for scientific research, medical therapeutics, biotechnology, etc. |
Specification
Wavelength
|
532nm
|
Output
power
|
6uJ x 5KHz
|
Beam Mode
|
TEM00, Multi-longitude
|
Power stability(RMS)
|
<5% @8hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling system
|
TEC
|
![]() |
![]() |
Characteriscics
| Stable and adjustable output power | |
| Over-temperature and over-current protection | |
| External modulation available | |
| Suitable for laser precision measuring, laser show applications, etc |
Specification
Wavelength
|
532nm
|
Output
power
|
1~100mW
|
Beam Mode
|
TEM00, Multi-longitude
|
Power stability(RMS)
|
<5% @4hours
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Cooling system
|
None
|
Drawing
![]() |
![]() |
Characteriscics
| drived by battery, small size, portable | |
| special safety parts design, to ensure users security | |
| Suitable for field laser work, laser DIY fans, etc |
Specification
Wavelength
|
532nm
|
Output
power
|
1~250mW
|
Beam Mode
|
TEM00, Multi-longitude
|
Beam Diammeter at
Aperture(mm)
|
1.2
|
Beam Divergence (full angle, mrad)
|
1.2±0.2
|
Power source
|
1x CR123
Battery
|
Drawing
![]() |







댓글 없음:
댓글 쓰기